Açıklama

tds

Code
A2X2Y-AF           AL/XLPE/PVC/HDPE
Voltage Rating
0.6/1 kV  AC     –    1000 / 1800 V  DC
Standards
IEC 60228Conductor
EN 61034Smoke Density
EN 50267Halogen Free
EN 60332-3Flame Retardant (Cat C)
Reaction to Fire Classification ( CPR )
EN 60332-1-2Flame Retardant
Conductor
Flexible Aluminum Conductor (Class 5)
Insulation
XLPE (Cross-linked Polyethylene)
Filler
PVC Filler
Armour
Sheath
HDPE (High Density Polyethylene) – UV Resistance
Waterproof ACC. AD8
Technical Data
Max. Operating Temperature:90°C
Short  Circuit  Temperature:250°C (max.5 sec)
Bending Radius:6D ( D : Overall Diameter )
Test Voltage:3,5 kV
Application:
For installation indoors and outdoors, in cable ducts, underground , in power or switching stations,local energy
distributions, industrial plants, where there is no risk of mechanical damage.Suitable for comparatively high
 maximum permissible conductor temperature.
Nominal Cross SectionOverall DiameterNet WeightDelivery LengthResistance at 20°CCurrent Carrying Capacity
(mm²)(mm)(kg/km)(m)(ohm/km)In Ground at 20°CIn Air at 30°C
1×1,5*6,947,6100019,25
1×2,5*7,455,0100011,55
1×4*8,066,110007,22
1×6*8,376,810004,81
1×109,6100,510003,08
1×1610,4125,010001,91
1×2512,5178,110001,20114106
1×3513,5216,710000,868136130
1×5014,7268,910000,641162161
1×7016,9352,210000,443199204
1×9518,8447,010000,320238252
1×12021,3558,610000,253272295
1×15023,0674,210000,206305339
1×18525,7829,310000,164347395
1×24028,71056,710000,125404472
1×30031,71305,010000,100457547
1×40035,21644,25000,0778525643
1×50040,22080,85000,0605601754
1×63044,12573,85000,0469687882
Nominal Cross SectionOverall DiameterNet WeightDelivery LengthResistance at 20°CCurrent Carrying Capacity
(mm²)(mm)(kg/km)(m)(ohm/km)In Ground at 20°CIn Air at 30°C
2×1,5*10,4118,7100019,25
2×2,5*11,3142,8100011,55
2×4*12,6179,810007,22
2×6*13,5221,110004,81
2×1015,8298,010003,08
2×1617,5377,910001,91
2×2521,5576,010001,20112102
2×3523,8722,010000,868135126
2×5026,3916,610000,641158149
2×7030,91237,810000,443196191
2×9535,01586,010000,320234234
2×12039,32015,710000,253268273
2×15043,02449,410000,206300311
2×18548,23047,25000,164342360
2×24054,33906,25000,125398427
Nominal Cross SectionOverall DiameterNet WeightDelivery LengthResistance at 20°CCurrent Carrying Capacity
(mm²)(mm)(kg/km)(m)(ohm/km)In Ground at 20°CIn Air at 30°C
3×1,5*10,9128,4100019,25
3×2,5*11,8155,8100011,55
3×4*13,2197,610007,22
3×6*14,2245,210004,81
3×1016,7332,310003,08
3×1618,5427,010001,91
3×2522,9651,210001,20112102
3×3525,3821,510000,868135126
3×5028,11059,810000,641158149
3×7033,21424,510000,443196191
3×9537,51839,910000,320234234
3×12042,22317,010000,253268273
3×15046,32827,910000,206300311
3×18551,83526,95000,164342360
3×24058,64530,05000,125398427
3×30064,45616,35000,100457507
3×40072,57151,12500,0778529600
Nominal Cross SectionOverall DiameterNet WeightDelivery LengthResistance at 20°CCurrent Carrying Capacity
(mm²)(mm)(kg/km)(m)(ohm/km)In Ground at 20°CIn Air at 30°C
3×16+1019,7482,610001,91 – 3,08
3×25+1623,9712,610001,20 – 1,91112102
3×35+1625,9864,710000,868 – 1,91135126
3×50+2529,41156,210000,641 – 1,20158149
3×70+3534,61548,110000,443 – 0,868196191
3×95+5039,01997,110000,320 – 0,641234234
3×120+7044,32570,15000,253 – 0,443268273
3×150+7047,73025,95000,206 – 0,443300311
3×185+9553,73785,65000,164 – 0,320342360
3×240+12060,44859,85000,125 – 0,253398427
3×300+15066,65965,52500,100 – 0,206457507
3×400+18574,87537,22500,0778 – 0,164529600
Nominal Cross SectionOverall DiameterNet WeightDelivery LengthResistance at 20°CCurrent Carrying Capacity
(mm²)(mm)(kg/km)(m)(ohm/km)In Ground at 20°CIn Air at 30°C
4×1,5*11,6147,3100019,25
4×2,5*12,7180,4100011,55
4×4*14,2231,010007,22
4×6*15,4288,510004,81
4×1018,2395,510003,08
4×1620,2513,110001,91
4×2525,1787,710001,20112102
4×3527,8997,710000,868135126
4×5031,11302,210000,641158149
4×7036,71749,35000,443196191
4×9541,62261,95000,320234234
4×12046,82862,55000,253268273
4×15051,33500,92500,206300311
4×18557,54357,82500,164342360
4×24065,05628,22500,125398427
4×30071,66884,92500,100457507
4×40080,68784,22500,0778529600
Nominal Cross SectionOverall DiameterNet WeightDelivery LengthResistance at 20°CCurrent Carrying Capacity
(mm²)(mm)(kg/km)(m)(ohm/km)In Ground at 20°CIn Air at 30°C
5×1,5*12,5173,5100019,25
5×2,5*13,7214,8100011,55
5×4*15,4278,210007,22
5×6*16,6354,910004,81
5×1019,8485,510003,08
5×1622,0634,210001,91
5×2527,5984,410001,20112102
5×3530,71260,210000,868135126
5×5034,51643,110000,641158149
5×7040,52226,55000,443196191
5×9546,02865,75000,320234234
5×12051,83623,35000,253268273
5×15056,84458,02500,206300311
5×18563,65545,32500,164342360
5×24071,97167,92500,125398427
5×30079,38762,22500,100457507
5×40089,411222,82500,0778529600
Note 1:
* Conductor resistance calculated theoretically.Conductor resistances are taken from EN 60228 Class-2 Aluminum values.
Note 2:
Current carrying capacities are valid at 30°C ambient temperature.